Enclosures made of fire-resistant plastic resin, class E2, according to ISO EN 11925-2: 2010, in areas near engine and electrical components.
Nominal diameter 200 mm.
Induction motor, thermally protected, with shaft mounted on bearing supports, combined with centrifugal impeller.
Equipped with an electronic timer for automatic operation at maximum speed, which can be set in the range 3-20′ during installation (default setting 3′).
High water resistance: IPX5 (if installed in a duct).
Adjustable speed via Vortice speed devices.
TECHNICAL DATA AND PERFORMANCE DATA
Absorbed power 1st gear (W)45
Frequency (Hz)50
Insulation classII°
IP44
Maximum ambient temperature for continuous operation (°C)60
Maximum. absorbed Current at max. speed (A)0.37
Maximum. absorbed Current in min. speed (A)0.22
Maximum. absorbed power at maximum speed (W)75
Voltage (V)220-240
Weight (Kg) 4.3
Delivery 1st gear (l/s)194.4
Delivery 1st speed (m³/h)700
Maximum delivery at maximum speed (l/s)263.9
Maximum delivery at maximum speed (m³/h)950
Pressure – 1st gear (mmH20)13
Pressure – 1st gear (Pa)127.5
Maximum pressure – maximum speed (mmH20)29
χMaximum pressure – maximum speed (mmH20)29
RPM max 2740
min1780
Sound pressure level Lp 3m – maximum speed49,0[dB (A)]
Sound pressure level Lp 3m – min speed39,6[dB (A)]