SKU: VRT-70807 Category:

CALDOPRO PLUS 5000 T

  • Cylindrical steel construction enclosed at the ends by air intake and exhaust grilles.
  • Steel grilles with vertical ribs.
  • Fan unit with three-phase single-speed motor and 5-blade aluminum rotor connected directly to the motor shaft.
  • 5000 W tubular heating element.
  • Control panel located on the top of the main cylindrical housing, made of self-extinguishing V0-rated ABS plastic, with a painted finish and integrated carrying/positioning handle.
  • Mechanical timer, 180 minutes maximum, allowing delayed shutdown.
  • Rotary heat output selector with three settings: off, half power, full power and fan only.
  • Self-resetting safety device, which acts as a thermal overload cut-out placed on the heating element.
  • Bent and painted steel legs, with anti-vibration bases.
  • Power cable complete with industrial grade five pin safety plug, 1800mm long.
  • Bulb-type room thermostat, capable of guaranteeing a more accurate reading.
  • IMQ safety certification.

TECHNICAL DATA AND PERFORMANCE DATA

  • Maximum absorbed current (A)7.2
  • Maximum absorbed power (W)5000
  • Frequency (Hz)50
  • Insulation classI°
  • IPX4
  • Voltage (V)400
  • Weight (Kg) 5.4
  • Devices with OXI standby mode
  • Auxiliary power consumption at minimum heat output – elmin (kW) 0,03
  • Auxiliary electricity consumption at nominal heat output – elmax (kW) 0.03
  • Standby auxiliary power consumption – elSB (kW) 0,03
  • Rate limiting control in mode NO
  • Check a distance NO
  • Check with black ball thermometer NO
  • Ambient temperature control for best possible operationNO
  • Ambient temperature control for presentation NO
  • Customizable launch control NO
  • Seasonal energy efficiency -? S (%) 36
  • Manual heat output of two or more phases without room temperature controlNO
  • Single-phase heat output without room temperature controlNO
  • Thermal power with room temperature control with NAI mechanical thermostat
  • Thermal power with electronic room temperature controlNO
  • Thermal power with electronic room temperature control and daily timerNO
  • Thermal power with electronic room temperature control and weekly timerNO
  • Continuous heat power – Pmax, c (kW) 5
  • Minimum heat output – Pmin (kW) 5
  • Nominal heat power – Pnom (kW)5

Technical Data Sheet

DIMENSIONS

  • Size A (mm)250
  • Size B (mm)330
  • Size C (mm)340

CERTIFICATES