QE 100/60/35 LL TP HCS

  • Scroll and front panel made of self-extinguishing ABS, rated V0.
  • Motor housing and filter frame made of ABS plastic.
  • 3-speed AC motor, shaft in bearings, connected to a centrifugal forward impeller, made of PBT.
  • Nominal air flows: 100 / 60 / 35 m3/h
  • G2 filter, with mechanical filter clogged alarm fully compliant with the ErP directive. N° 1253/2014/UE, in force since January 1, 2018.
  • EVO timer function: activation/deactivation of exhaust fan is done via light control. the built-in electronics allow you to set, during installation, the start/pause delay when the product is on/off (the respective delays can be set to 0, 45, 90 or 120 seconds and 6, 10, 15 or 21 minutes ).
  • HCS function: activation/deactivation of the exhaust fan is performed according to the ambient relative humidity values detected by the HCS (Humidity Control System) sensor integrated in the built-in electronic. The system works in two different modes, ensuring the best environmental conditions:
    • Limit exceeded: the product starts working when the relative humidity of the environment exceeds a given limit, which can be set by the installer to four values: 60%, 70%, 80%, 90% RH (70% is the factory setting). The fan stops working when the RH level drops below 15% of the preset RH value or after two hours of continuous operation.
    • Rapid increase in RH value: the product starts automatically as a result of a sudden RH increase (​​ [encoded_tag_closed]​​ 20% in 10 minutes) and stops immediately to extract air when the RH level falls below 15% of the preset RH value or after two hours of continuous operation.>
    • Possibility of connection with an external switch for manual control of the product, regardless of the HR value detected in the air (for example to prevent activation of the exhaust fan when the external humidity is too high).
    • It is also possible to set, during installation, the continuous operation mode to the minimum speed (Continuous room ventilation), switching to a higher speed option through the activation/deactivation of the light control and thus to the values detected by the HR sensor (mode Boost).

TECHNICAL DATA AND PERFORMANCE DATA

  • Absorbed power 1st gear (W)9
  • Frequency (Hz)50
  • Insulation classII°
  • IP45
  • Maximum ambient temperature for continuous operation (°C)50
  • Maximum. absorbed Current at max. speed (A)0.17
  • Maximum. absorbed Current in min. speed (A)0.11
  • Maximum. absorbed power at maximum speed (W)26
  • Nominal diameter (mm)80
  • Ø Discharge hole (mm)70
  • Voltage (V)220-240
  • Weight (Kg) 2.33
  • Delivery 1st gear (l/s)9.7
  • Delivery 1st gear (m³/h)35
  • Maximum delivery at maximum speed (l/s)27.8
  • Maximum delivery at maximum speed (m³/h)100
  • Pressure – 1st gear (mmH20)10
  • Pressure – 1st gear (Pa)98
  • Max pressure – max speed (mmH20)36
  • Maximum pressure – maximum speed (Pa)353
  • RPM max 1570
  • revolutions min.855
  • Lw audio power ​​ [wpcodeself] ​​ – min speed37.3 [wpcodeself][dB(A)]
  • Sound power Lw ​​ [wpcodeself] ​​ – max speed52[dB(A)]
  • Sound pressure level Lp in free field ​​ [wpcodeself] ​​ 3 m maximum speed31.5[dB(A)]
  • Sound pressure level Lp in free field ​​ [wpcodeself] ​​ Speed 3 m min16.8[dB(A)]

Technical Data Sheet

DIMENSIONS

  • Size A (mm)262
  • Size B (mm) 262
  • Size C (mm)115.5
  • Size D (mm)80
  • Size E (mm)73
  • Size F (mm)79
  • Size G (mm)71,5
  • Size H (mm)90