Material: UV-resistant plastic (prevents aging caused by exposure to sunlight).
Nominal diameter 100 mm.
Motor protected against thermal overload, with shaft rotation in bearings, connected to a screw-type thermoplastic impeller with vane profile vanes.
Maximum air flow: 85 m3/h.
It incorporates the electronic presence detector with an infrared sensor and an electronic timer designed to turn off the engine automatically after a set interval, selectable during installation in the range 3′-20′ (default setting 3′), after starting room.
Non-return damper mounted on outlet port.
IMQ SAFETY and IMQ PERFORMANCE certifications.
Eddy speed controller.
TECHNICAL DATA AND PERFORMANCE DATA
Frequency (Hz) 50
Insulation class II°
IP X4
Maximum absorbed current (A) 0.09
Μέγιστη απορροφούμενη ισχύς (W) 15
Maximum absorbed power at maximum speed (W) 15
Maximum ambient temperature for continuous operation (°C) 50